ผลิตภัณฑ์ Siemens

อุปกรณ์ควบคุมและป้องกันไฟฟ้าอื่นๆ


3LD2064-0TB53

Siemens

Another Image zoom-on-hover effect

SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 16 A, operating power / at AC-23 A 400 V: 7.5 kW, Molded plastic encapsulation for metric cable gland, rotary operating mechanism, red/yellow Main and EMERGENCY OFF switch SENTRON 3LD2 for the safe shutdown of loads in many areas, e.g. for three-phase motors, air conditioning and ventilation systems, in machining and processing machines in mechanical and conveyor system construction, in the chemical or in the food and beverage industry. Modular design, fast and easy mounting of auxiliary switches, N-PE terminal, or 4th pole. Optimum disconnection of 16 A of 250 A from the power supply due to the locking capability of the rotary operating mechanism. Degree of protection IP65 with encapsulated enclosure for outdoor applications. Versatile and can be used worldwide thanks to international IEC, UL, CCC, and shipbuilding approvals. The 3LD main and EMERGENCY-OFF switches are available in a wide range of variants for front mounting, mounting plate, DIN rail, or installation in distribution boards, optionally with direct or door-coupling rotary operating mechanism. 3LD2 is also available in variants for DC applications. Main and EMERGENCY-OFF switch 3LD - End-to-end safety for users and systems.

3LD2130-0TK13

Siemens

Another Image zoom-on-hover effect

SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 25 A, operating power / at AC-23 A 400 V: 9.5 kW, installation in distribution boards, knob-operated mechanism, Red / yellow, handle direct at the switch Main and EMERGENCY OFF switch SENTRON 3LD2 for the safe shutdown of loads in many areas, e.g. for three-phase motors, air conditioning and ventilation systems, in machining and processing machines in mechanical and conveyor system construction, in the chemical or in the food and beverage industry. Modular design, fast and easy mounting of auxiliary switches, N-PE terminal, or 4th pole. Optimum disconnection of 16 A of 250 A from the power supply due to the locking capability of the rotary operating mechanism. Degree of protection IP65 with encapsulated enclosure for outdoor applications. Versatile and can be used worldwide thanks to international IEC, UL, CCC, and shipbuilding approvals. The 3LD main and EMERGENCY-OFF switches are available in a wide range of variants for front mounting, mounting plate, DIN rail, or installation in distribution boards, optionally with direct or door-coupling rotary operating mechanism. 3LD2 is also available in variants for DC applications. Main and EMERGENCY-OFF switch 3LD - End-to-end safety for users and systems.

3LD2164-1GP53

Siemens

Another Image zoom-on-hover effect

SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 25 A, operating power / at AC-23 A 400 V: 9.5 kW, Molded plastic encapsulation for metric cable gland, 1 NC, 1 NO, rotary operating mechanism, red/yellow Main and EMERGENCY OFF switch SENTRON 3LD2 for the safe shutdown of loads in many areas, e.g. for three-phase motors, air conditioning and ventilation systems, in machining and processing machines in mechanical and conveyor system construction, in the chemical or in the food and beverage industry. Modular design, fast and easy mounting of auxiliary switches, N-PE terminal, or 4th pole. Optimum disconnection of 16 A of 250 A from the power supply due to the locking capability of the rotary operating mechanism. Degree of protection IP65 with encapsulated enclosure for outdoor applications. Versatile and can be used worldwide thanks to international IEC, UL, CCC, and shipbuilding approvals. The 3LD main and EMERGENCY-OFF switches are available in a wide range of variants for front mounting, mounting plate, DIN rail, or installation in distribution boards, optionally with direct or door-coupling rotary operating mechanism. 3LD2 is also available in variants for DC applications. Main and EMERGENCY-OFF switch 3LD - End-to-end safety for users and systems.

3LD2264-0TB53

Siemens

Another Image zoom-on-hover effect

SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 32 A, operating power / at AC-23 A 400 V: 11.5 kW, molded-plastic encapsulation for metric cable gland, rotary operating mechanism, red/yellow Main and EMERGENCY OFF switch SENTRON 3LD2 for the safe shutdown of loads in many areas, e.g. for three-phase motors, air conditioning and ventilation systems, in machining and processing machines in mechanical and conveyor system construction, in the chemical or in the food and beverage industry. Modular design, fast and easy mounting of auxiliary switches, N-PE terminal, or 4th pole. Optimum disconnection of 16 A of 250 A from the power supply due to the locking capability of the rotary operating mechanism. Degree of protection IP65 with encapsulated enclosure for outdoor applications. Versatile and can be used worldwide thanks to international IEC, UL, CCC, and shipbuilding approvals. The 3LD main and EMERGENCY-OFF switches are available in a wide range of variants for front mounting, mounting plate, DIN rail, or installation in distribution boards, optionally with direct or door-coupling rotary operating mechanism. 3LD2 is also available in variants for DC applications. Main and EMERGENCY-OFF switch 3LD - End-to-end safety for users and systems.

3LD2565-1GP53

Siemens

Another Image zoom-on-hover effect

SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 63 A, operating power / at AC-23 A 400 V: 22 kW, Molded plastic encapsulation for metric cable gland, 1 NC, 1 NO, rotary operating mechanism, red/yellow Main and EMERGENCY OFF switch SENTRON 3LD2 for the safe shutdown of loads in many areas, e.g. for three-phase motors, air conditioning and ventilation systems, in machining and processing machines in mechanical and conveyor system construction, in the chemical or in the food and beverage industry. Modular design, fast and easy mounting of auxiliary switches, N-PE terminal, or 4th pole. Optimum disconnection of 16 A of 250 A from the power supply due to the locking capability of the rotary operating mechanism. Degree of protection IP65 with encapsulated enclosure for outdoor applications. Versatile and can be used worldwide thanks to international IEC, UL, CCC, and shipbuilding approvals. The 3LD main and EMERGENCY-OFF switches are available in a wide range of variants for front mounting, mounting plate, DIN rail, or installation in distribution boards, optionally with direct or door-coupling rotary operating mechanism. 3LD2 is also available in variants for DC applications. Main and EMERGENCY-OFF switch 3LD - End-to-end safety for users and systems.

3LD2804-0TK53

Siemens

Another Image zoom-on-hover effect

SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 125 A, operating power / at AC-23 A 400 V: 45 kW, front-mounted, rotary operating mechanism, Red / yellow, 4-hole mounting of the handle Main and EMERGENCY OFF switch SENTRON 3LD2 for the safe shutdown of loads in many areas, e.g. for three-phase motors, air conditioning and ventilation systems, in machining and processing machines in mechanical and conveyor system construction, in the chemical or in the food and beverage industry. Modular design, fast and easy mounting of auxiliary switches, N-PE terminal, or 4th pole. Optimum disconnection of 16 A of 250 A from the power supply due to the locking capability of the rotary operating mechanism. Degree of protection IP65 with encapsulated enclosure for outdoor applications. Versatile and can be used worldwide thanks to international IEC, UL, CCC, and shipbuilding approvals. The 3LD main and EMERGENCY-OFF switches are available in a wide range of variants for front mounting, mounting plate, DIN rail, or installation in distribution boards, optionally with direct or door-coupling rotary operating mechanism. 3LD2 is also available in variants for DC applications. Main and EMERGENCY-OFF switch 3LD - End-to-end safety for users and systems.

3LD2030-0TK13

Siemens

Another Image zoom-on-hover effect

SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 16 A, operating power / at AC-23 A 400 V: 7.5 kW, installation in distribution boards, knob-operated mechanism, Red / yellow, handle direct at the switch Main and EMERGENCY OFF switch SENTRON 3LD2 for the safe shutdown of loads in many areas, e.g. for three-phase motors, air conditioning and ventilation systems, in machining and processing machines in mechanical and conveyor system construction, in the chemical or in the food and beverage industry. Modular design, fast and easy mounting of auxiliary switches, N-PE terminal, or 4th pole. Optimum disconnection of 16 A of 250 A from the power supply due to the locking capability of the rotary operating mechanism. Degree of protection IP65 with encapsulated enclosure for outdoor applications. Versatile and can be used worldwide thanks to international IEC, UL, CCC, and shipbuilding approvals. The 3LD main and EMERGENCY-OFF switches are available in a wide range of variants for front mounting, mounting plate, DIN rail, or installation in distribution boards, optionally with direct or door-coupling rotary operating mechanism. 3LD2 is also available in variants for DC applications. Main and EMERGENCY-OFF switch 3LD - End-to-end safety for users and systems.

3LD2054-1TP53

Siemens

Another Image zoom-on-hover effect

SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 16 A, operating power / at AC-23 A 400 V: 7.5 kW, front-mounted, 1 NC, 1 NO, rotary operating mechanism, Red / yellow, Central mounting 22.5 mm of the handle Main and EMERGENCY OFF switch SENTRON 3LD2 for the safe shutdown of loads in many areas, e.g. for three-phase motors, air conditioning and ventilation systems, in machining and processing machines in mechanical and conveyor system construction, in the chemical or in the food and beverage industry. Modular design, fast and easy mounting of auxiliary switches, N-PE terminal, or 4th pole. Optimum disconnection of 16 A of 250 A from the power supply due to the locking capability of the rotary operating mechanism. Degree of protection IP65 with encapsulated enclosure for outdoor applications. Versatile and can be used worldwide thanks to international IEC, UL, CCC, and shipbuilding approvals. The 3LD main and EMERGENCY-OFF switches are available in a wide range of variants for front mounting, mounting plate, DIN rail, or installation in distribution boards, optionally with direct or door-coupling rotary operating mechanism. 3LD2 is also available in variants for DC applications. Main and EMERGENCY-OFF switch 3LD - End-to-end safety for users and systems.

3LD2203-0TK53

Siemens

Another Image zoom-on-hover effect

SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 32 A, operating power / at AC-23 A 400 V: 11.5 kW, front-mounted, rotary operating mechanism, Red / yellow, 4-hole mounting of the handle Main and EMERGENCY OFF switch SENTRON 3LD2 for the safe shutdown of loads in many areas, e.g. for three-phase motors, air conditioning and ventilation systems, in machining and processing machines in mechanical and conveyor system construction, in the chemical or in the food and beverage industry. Modular design, fast and easy mounting of auxiliary switches, N-PE terminal, or 4th pole. Optimum disconnection of 16 A of 250 A from the power supply due to the locking capability of the rotary operating mechanism. Degree of protection IP65 with encapsulated enclosure for outdoor applications. Versatile and can be used worldwide thanks to international IEC, UL, CCC, and shipbuilding approvals. The 3LD main and EMERGENCY-OFF switches are available in a wide range of variants for front mounting, mounting plate, DIN rail, or installation in distribution boards, optionally with direct or door-coupling rotary operating mechanism. 3LD2 is also available in variants for DC applications. Main and EMERGENCY-OFF switch 3LD - End-to-end safety for users and systems.

3LD2254-1TL53

Siemens

Another Image zoom-on-hover effect

SENTRON, Switch disconnector 3LD, emergency switching-off switch, 4- pole, Iu: 32 A, operating power / at AC-23 A 400 V: 11.5 kW, front-mounted, rotary operating mechanism, Red / yellow, central mounting 22.5 mm of the handle Main and EMERGENCY OFF switch SENTRON 3LD2 for the safe shutdown of loads in many areas, e.g. for three-phase motors, air conditioning and ventilation systems, in machining and processing machines in mechanical and conveyor system construction, in the chemical or in the food and beverage industry. Modular design, fast and easy mounting of auxiliary switches, N-PE terminal, or 4th pole. Optimum disconnection of 16 A of 250 A from the power supply due to the locking capability of the rotary operating mechanism. Degree of protection IP65 with encapsulated enclosure for outdoor applications. Versatile and can be used worldwide thanks to international IEC, UL, CCC, and shipbuilding approvals. The 3LD main and EMERGENCY-OFF switches are available in a wide range of variants for front mounting, mounting plate, DIN rail, or installation in distribution boards, optionally with direct or door-coupling rotary operating mechanism. 3LD2 is also available in variants for DC applications. Main and EMERGENCY-OFF switch 3LD - End-to-end safety for users and systems.

3LD2003-0TK53

Siemens

Another Image zoom-on-hover effect

SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 16 A, operating power / at AC-23 A 400 V: 7.5 kW, front-mounted, rotary operating mechanism, Red / yellow, 4-hole mounting of the handle Main and EMERGENCY OFF switch SENTRON 3LD2 for the safe shutdown of loads in many areas, e.g. for three-phase motors, air conditioning and ventilation systems, in machining and processing machines in mechanical and conveyor system construction, in the chemical or in the food and beverage industry. Modular design, fast and easy mounting of auxiliary switches, N-PE terminal, or 4th pole. Optimum disconnection of 16 A of 250 A from the power supply due to the locking capability of the rotary operating mechanism. Degree of protection IP65 with encapsulated enclosure for outdoor applications. Versatile and can be used worldwide thanks to international IEC, UL, CCC, and shipbuilding approvals. The 3LD main and EMERGENCY-OFF switches are available in a wide range of variants for front mounting, mounting plate, DIN rail, or installation in distribution boards, optionally with direct or door-coupling rotary operating mechanism. 3LD2 is also available in variants for DC applications. Main and EMERGENCY-OFF switch 3LD - End-to-end safety for users and systems.

8US1251-5DS10

Siemens

Another Image zoom-on-hover effect

Device adapter S00/S0, 25A, for 60 mm busbar system, 45x 200 mm long special lines welded-on AWG 12, 99 mm long spacer enclosed Mounting rail screwed on 8US busbar system for setting up protective devices such as fuse switch disconnectors and circuit breakers - safe, space-saving and clearly laid out. The use of the 8US busbar systems from Siemens gives a number of options for installing rail-adaptable connecting, switching and installation devices. Cost-effective electrotechnical enhancement of modern distribution boards is possible due to their small footprint, compact design and quick assembly contacts. Mounting is on longitudinal stays and the rail gapis 60 mm. Key features of the Siemens 8US busbar systems: 1. Mechanical fixing and electrical contacting in a single step. 2. Worldwide approval and therefore worldwide use in mechanical and plant engineering. 3. Easy replacement of individual devices or entire combinations. 4. Time savings and cost reductions in installation with preassembled load feeders. 5. High operational safety with finger-safe adapter and device holder covers. 6. Large range of busbars can be used for easy adjustment to currents of up to 1,600 A.